CONTATTI +39 0422 841262 info@astra.tv.it

EX 14 AZ


EX 14 AZ

IP 54, IP 67, ATEX SAFETY DOOR CONTACTS
Pre-wired safety door contact for explosion-proof applications, suitable for systems installed in explosion hazard environments.Forced opening with separate actuator, self-extinguishing nylon housing, slow-action switching. Its small size makes it suitable for special applications. Models with side wire outlet are available on request.
TECHNICAL DATA
Ie/Ue
2A/230VAC
0.25A/230VDC

Ith
2A

Ui
250V

function category
AC-15 / DC-13

mechanical lifetime
> 1,000,000 cycles

protection level
IP 65

switching
slow action forced opening

contacts
1 N.O.

wire diameter
2x 0.75mm2

actuation force
2 - 3.5N

forced opening
3.5mm

operating temperature
-20°C +65°C

MATERIALS
body
nylon - V0

contacts
silver

actuator
stainless steel

REGULATIONS
2014/33/UE
EN 81-20/50
APPROVALS
TÜV

ACTUATORS
CH 14 AZ
to be ordered separately
ORDERING CODES
ORDERING CODES

IP 54, IP 67, ATEX SAFETY DOOR CONTACTS

PRODUCTS

Notice: this website and third parties’ tools use cookies necessary for its operation and useful for the purposes described in the cookie policy. For more information on our cookie policy click on cookie policy. You accept all cookies by clicking “ACCEPT”